package tun
|
|
|
|
// This manages the tun driver to send/recv packets to/from applications
|
|
|
|
// TODO: Connection timeouts (call Conn.Close() when we want to time out)
|
|
// TODO: Don't block in reader on writes that are pending searches
|
|
|
|
import (
|
|
"errors"
|
|
"fmt"
|
|
"net"
|
|
|
|
"github.com/Arceliar/phony"
|
|
"golang.zx2c4.com/wireguard/tun"
|
|
|
|
"github.com/yggdrasil-network/yggdrasil-go/src/address"
|
|
"github.com/yggdrasil-network/yggdrasil-go/src/core"
|
|
"github.com/yggdrasil-network/yggdrasil-go/src/defaults"
|
|
"github.com/yggdrasil-network/yggdrasil-go/src/ipv6rwc"
|
|
)
|
|
|
|
type MTU uint16
|
|
|
|
// TunAdapter represents a running TUN interface and extends the
|
|
// yggdrasil.Adapter type. In order to use the TUN adapter with Yggdrasil, you
|
|
// should pass this object to the yggdrasil.SetRouterAdapter() function before
|
|
// calling yggdrasil.Start().
|
|
type TunAdapter struct {
|
|
rwc *ipv6rwc.ReadWriteCloser
|
|
log core.Logger
|
|
addr address.Address
|
|
subnet address.Subnet
|
|
mtu uint64
|
|
iface tun.Device
|
|
phony.Inbox // Currently only used for _handlePacket from the reader, TODO: all the stuff that currently needs a mutex below
|
|
//mutex sync.RWMutex // Protects the below
|
|
isOpen bool
|
|
isEnabled bool // Used by the writer to drop sessionTraffic if not enabled
|
|
config struct {
|
|
name InterfaceName
|
|
mtu InterfaceMTU
|
|
}
|
|
}
|
|
|
|
// Gets the maximum supported MTU for the platform based on the defaults in
|
|
// defaults.GetDefaults().
|
|
func getSupportedMTU(mtu uint64) uint64 {
|
|
if mtu < 1280 {
|
|
return 1280
|
|
}
|
|
if mtu > MaximumMTU() {
|
|
return MaximumMTU()
|
|
}
|
|
return mtu
|
|
}
|
|
|
|
// Name returns the name of the adapter, e.g. "tun0". On Windows, this may
|
|
// return a canonical adapter name instead.
|
|
func (tun *TunAdapter) Name() string {
|
|
if name, err := tun.iface.Name(); err == nil {
|
|
return name
|
|
}
|
|
return ""
|
|
}
|
|
|
|
// MTU gets the adapter's MTU. This can range between 1280 and 65535, although
|
|
// the maximum value is determined by your platform. The returned value will
|
|
// never exceed that of MaximumMTU().
|
|
func (tun *TunAdapter) MTU() uint64 {
|
|
return getSupportedMTU(tun.mtu)
|
|
}
|
|
|
|
// DefaultName gets the default TUN interface name for your platform.
|
|
func DefaultName() string {
|
|
return defaults.GetDefaults().DefaultIfName
|
|
}
|
|
|
|
// DefaultMTU gets the default TUN interface MTU for your platform. This can
|
|
// be as high as MaximumMTU(), depending on platform, but is never lower than 1280.
|
|
func DefaultMTU() uint64 {
|
|
return defaults.GetDefaults().DefaultIfMTU
|
|
}
|
|
|
|
// MaximumMTU returns the maximum supported TUN interface MTU for your
|
|
// platform. This can be as high as 65535, depending on platform, but is never
|
|
// lower than 1280.
|
|
func MaximumMTU() uint64 {
|
|
return defaults.GetDefaults().MaximumIfMTU
|
|
}
|
|
|
|
// Init initialises the TUN module. You must have acquired a Listener from
|
|
// the Yggdrasil core before this point and it must not be in use elsewhere.
|
|
func New(rwc *ipv6rwc.ReadWriteCloser, log core.Logger, opts ...SetupOption) (*TunAdapter, error) {
|
|
tun := &TunAdapter{
|
|
rwc: rwc,
|
|
log: log,
|
|
}
|
|
for _, opt := range opts {
|
|
tun._applyOption(opt)
|
|
}
|
|
return tun, tun._start()
|
|
}
|
|
|
|
func (tun *TunAdapter) _start() error {
|
|
if tun.isOpen {
|
|
return errors.New("TUN module is already started")
|
|
}
|
|
tun.addr = tun.rwc.Address()
|
|
tun.subnet = tun.rwc.Subnet()
|
|
prefix := address.GetPrefix()
|
|
addr := fmt.Sprintf("%s/%d", net.IP(tun.addr[:]).String(), 8*len(prefix[:])-1)
|
|
if tun.config.name == "none" || tun.config.name == "dummy" {
|
|
tun.log.Debugln("Not starting TUN as ifname is none or dummy")
|
|
tun.isEnabled = false
|
|
go tun.write()
|
|
return nil
|
|
}
|
|
mtu := uint64(tun.config.mtu)
|
|
if tun.rwc.MaxMTU() < mtu {
|
|
mtu = tun.rwc.MaxMTU()
|
|
}
|
|
if err := tun.setup(string(tun.config.name), addr, mtu); err != nil {
|
|
return err
|
|
}
|
|
if tun.MTU() != mtu {
|
|
tun.log.Warnf("Warning: Interface MTU %d automatically adjusted to %d (supported range is 1280-%d)", tun.config.mtu, tun.MTU(), MaximumMTU())
|
|
}
|
|
tun.rwc.SetMTU(tun.MTU())
|
|
tun.isOpen = true
|
|
tun.isEnabled = true
|
|
go tun.read()
|
|
go tun.write()
|
|
return nil
|
|
}
|
|
|
|
// IsStarted returns true if the module has been started.
|
|
func (tun *TunAdapter) IsStarted() bool {
|
|
var isOpen bool
|
|
phony.Block(tun, func() {
|
|
isOpen = tun.isOpen
|
|
})
|
|
return isOpen
|
|
}
|
|
|
|
// Start the setup process for the TUN adapter. If successful, starts the
|
|
// read/write goroutines to handle packets on that interface.
|
|
func (tun *TunAdapter) Stop() error {
|
|
var err error
|
|
phony.Block(tun, func() {
|
|
err = tun._stop()
|
|
})
|
|
return err
|
|
}
|
|
|
|
func (tun *TunAdapter) _stop() error {
|
|
tun.isOpen = false
|
|
// by TUN, e.g. readers/writers, sessions
|
|
if tun.iface != nil {
|
|
// Just in case we failed to start up the iface for some reason, this can apparently happen on Windows
|
|
tun.iface.Close()
|
|
}
|
|
return nil
|
|
}
|